Skip to main content
Norfolk Building Group Monogram
Norfolk Building GroupCommercial Contracting & Civil Works
Compliance

Fire Safety & Compliance Works

Certified Fire Door Upgrades, Fire Stopping & FRA Remedial Works. Following a Fire Risk Assessment (FRA), remedial action is legally mandated under the Regulatory Reform (Fire Safety) Order. We supply, install, and certify FD30 and FD60 assemblies, intumescent fire stopping, and passive fire containment.

Standards
Regulatory Reform (Fire Safety) Order 2005 & Fire Safety Regs 2022
Delivery
Live Operational Containment
Compliance
CHAS Accredited Contractor
Fire Safety & Compliance Works
CHAS Accredited
COVERAGE: Norfolk Based, Nationwide Service
Executive Technical Scope

Technical Specification & Engineering Scope

Scope Overview

Norfolk Building Group installs certified FD30 and FD60 timber and steel fire doorsets, passive fire compartmentation, and structural fire stopping nationwide across the UK. Working to BS 476-22 and BS EN 1634-1 standards, our teams deliver urgent remedial works following Fire Risk Assessments (FRA) to ensure commercial building compliance.

CHAS Accredited ContractorBritish Standards CertifiedDirect Director Supervision

Engineering & Compliance Matrix

Verified Standards
Statutory Framework
Regulatory Reform (Fire Safety) Order 2005 & Fire Safety Regs 2022
Building Regulations
Approved Document B (Fire Safety, Volume 2 - Commercial)
Fire Resistance Tests
BS 476-22 & BS EN 1634-1 certified performance
Doorset Ratings
Certified FD30S (30-min smoke) & FD60S (60-min smoke) assemblies
Penetration Sealing
BS EN 1366-3 compliant intumescent collars, wraps & batts
Certified Ironmongery
BS EN 1154 closers, BS EN 1935 hinges, BS EN 1125 panic exit

Capabilities in Fire Safety

Each package is delivered under direct senior site management, with dedicated RAMS, scheduled progress reporting, and full containment around live operations.

FD30S and FD60S certified commercial fire doorset supply, installation, and certification

Delivered in strict compliance with current British Standards and CDM regulations.

Fire door remedial works, frame re-bating, intumescent strip and cold smoke seal renewals

Delivered in strict compliance with current British Standards and CDM regulations.

CE and UKCA marked fire door hardware (BS EN 1154 overhead closers, BS EN 1906 handles, BS EN 1935 hinges)

Delivered in strict compliance with current British Standards and CDM regulations.

Certified intumescent fire stopping around MEP service penetrations (cables, ducts, pipes)

Delivered in strict compliance with current British Standards and CDM regulations.

Fire-rated compartmentation stud walls and fire barrier mineral wool quilt installations

Delivered in strict compliance with current British Standards and CDM regulations.

Remedial works programmes addressing Fire Risk Assessment (FRA) statutory notices

Delivered in strict compliance with current British Standards and CDM regulations.

Emergency escape route door upgrades, panic push-bars (BS EN 1125), and compliant signage

Delivered in strict compliance with current British Standards and CDM regulations.

Comprehensive fire doorset registers, asset tagging, and installation sign-off certificates

Delivered in strict compliance with current British Standards and CDM regulations.

Built Around Active Commercial Facilities

Commercial premises rarely have the luxury of closing during building works. Norfolk Building Group operates proven protocols to protect daily business activities:

Regulatory Reform (Fire Safety) Order 2005 and Fire Safety (England) Regulations 2022
Building Regulations Approved Document B (Fire safety, Volume 2 - Commercial)
BS 476-22 and BS EN 1634-1 fire door fire resistance testing standards
Third-party certified fire doorsets and BS EN 1366-3 compliant penetration sealing
Full Risk Assessments and Method Statements (RAMS) issued prior to site arrival
CHAS accredited safety standards across all trades and operatives
Direct Management AccountabilityNorfolk Based
“Our focus is regional certainty: you deal directly with directors and senior site managers who know Norfolk, understand commercial pressures, and take personal responsibility for on-time handover.”
SH
Stefano Harding
Managing Director, Norfolk Building Group
Technical Guidance & Compliance

Frequently Addressed Technical Enquiries

Clear technical answers regarding British Standards compliance, operational containment, and delivery parameters for commercial clients across Norfolk.

Standards & Scope

What is the difference between FD30 and FD30S fire doors?

An FD30 door resists fire and heat for a minimum of 30 minutes under BS 476-22 testing. An FD30S door incorporates integrated intumescent seals AND flexible acoustic or brush cold smoke seals, preventing the passage of toxic cold smoke along escape routes, which is mandated by Building Regulations Approved Document B.

Containment & Execution

What is required following a commercial Fire Risk Assessment (FRA)?

When an FRA identifies non-compliances (such as excessive door gaps over 4mm, damaged intumescent strips, uncertified closers, or unsealed service penetrations), the designated Responsible Person is legally obligated under the Fire Safety Order to carry out qualified remedial works and obtain formal verification records.

Compliance & Handover

What is passive fire stopping around MEP services?

Passive fire stopping restores the fire rating of compartment walls and floors penetrated by electrical cables, conduits, and plastic pipework. We install intumescent mastic wraps, pipe collars that crush pipes closed when exposed to heat, and ablative-coated mineral batts rated to BS EN 1366-3.

Hub-to-Spoke Knowledge • Technical Research

Related Technical Insights & Specification Guides

View Full 2026 Benchmark→
Original Technical Research

UK Commercial Building & Facilities Benchmark 2026

Consolidated specification indices, indicative cost per m² benchmarks, British Standards tolerances, and compliance criteria for facilities managers nationwide.

£/m² Indices • BRCGS • TR34Read Benchmark →
Technical Specification Guide

Hygienic Wall Cladding for UK Food Facilities: BioClad vs Altro Whiterock

Antimicrobial performance, thermoformed corner detailing, and active-shift installation protocols compliant with BRCGS Food Safety Issue 9.

BioClad • Altro • Class 0Read Guide →
Commercial Sector Scope

Commercial Sectors We Support Nationwide

Tailored site management, shift patterns, and compliance frameworks for food plants, logistics hubs, retail, and commercial property estates.

8 Core Commercial SectorsExplore Sectors →

Ready to Discuss Your Fire Safety Package?

Send tender documentation, schedule an initial site visit, or discuss reactive maintenance agreements with our Norwich and Tharston team.